Cisco Aggregation Services Routers C1-ASR1002-HX/K9
HARGA HUBUNGI KAMI
C1-ASR1002-HX/K9 Specification |
|
| Physical specifications | Height: 3.5 in. (88.9 mm)
Width: 17.3 in. (439.4 mm) Depth: 19.25 in. (489.0 mm) Weight: ● 34 lb (15.45 kg) (with dual AC power supplies) ● 34 lb (15.45 kg) (with dual DC power supplies) |
| Default memory | 16-GB DRAM shared across route processor, ESP, and MIP |
| Number of SIPs or Ethernet line cards supported | Integrated in chassis |
| Shared port adapters | N/A |
| Ethernet port adapters | 1 EPA slot |
| Cisco ASR 1000 Series ESP | Integrated in chassis |
| Route processor | Integrated in the chassis: Cisco ASR 1002-HX Series Route Processor |
| Redundancy | Software: Yes |
| Built-in Gigabit Ethernet ports | Yes: 8 Gigabit Ethernet SFP ports |
| Built-in 10 Gigabit Ethernet port | Yes: Eight 10 Gigabit Ethernet Small Form-Factor Plus Pluggable (SFP+) ports
Note:Built-in 10-GB ports cannot be reduced to 1-GB speed. |
| Network interface module | Yes |
| ESP support | Cisco ASR 1000 Series 100-Gbps ESP (ASR1000-ESP100) equivalent |
| ESP bandwidth | 100 Gbps |
| ESP memory | Share the same control memory on route processor |
| SIPs and Ethernet line cards | Integrated in chassis: not upgradable |
| Embedded hardware-based encryption | Yes: Up to 25-Gbps crypto support throughput |
| Minimum Cisco IOS XE Software release | Cisco IOS XE Software Release 16.2.1S |
| Rack-mounting | Yes: 19-inch |
| Wall-mounting | No |
| External USB flash memory | 1-GB USB flash-memory support |
| Redundant power supply | Yes: Dual power supplies by default; option of either AC or DC power supply
Note: A mix of one AC and one DC power supply is not supported. |
| Power input | Worldwide ranging AC input range (85 to 264 VAC)
Worldwide ranging DC (-40 to -72; -48V nominal) |
| Power consumption | ● Maximum (DC): 500W
● Maximum (AC): 500W |
| Airflow | Front-to-back |
| Operating temperature (nominal) | 32 to 104°F (0 to 40°C) |
| Operating temperature (short-term) | 32 to 122°F (0 to 50°C) |
| Operating humidity (nominal) (relative humidity) | 10 to 85% |
| Operating humidity (short-term) | 5 to 90% |
| Storage temperature | -40 to 150°F
(-40 to 70°C) |
| Storage humidity (relative humidity) | 5 to 95% |
| Operating altitude | -500 to 10,000 feet (152 to 3048 meters) |
| Network Equipment Building Standards (NEBS) | GR-1089 and GR-63 |
| EMC standards | Emissions
● FCC 47CFR15 Class A ● AS/NZS CISPR 22 ● CISPR 22 Class A ● EN55022 Class A ● ICES-003 Class A ● VCCI Class A ● CNS-13438 Class A ● EN61000-3-2 ● EN61000-3-3 Immunity ● IEC/EN61000-4-2 Electrostatic Discharge Immunity ● IEC/EN61000-4-3 Radiated Immunity ● IEC/EN61000-4-4 EFT-B Immunity ● IEC/EN61000-4-5 Surge ● IEC/EN61000-4-6 Immunity to Conducted Disturbances ● IEC/EN61000-4-8 Power Frequency Magnetic Field Immunity ● IEC/EN61000-4-11 Voltage Dips, Short Interruptions, and Voltage Variations ETSI/EN ● EN55022/CISPR 22 Information Technology Equipment (Emissions) ● EN55024/CISPR 24 Information Technology Equipment (Immunity) ● EN300 386 Telecommunications Network Equipment ● EN50082-1/EN61000-6-1 Generic Immunity Standard |
| Safety Standard | UL60950-1
CSA C22.2 No. 60950-1-03 EN 60950-1 IEC 60950-1 AS/NZS 60950.1 |