Cisco Nexus 3064-X, 48 SFP+ and 4 QSFP+ ports, with enhanced scale, low latency (N3K-C3064PQ-10GX)

Rp280.419.300

SKU: N3K-C3064PQ-10GX Kategori: , , Tag:
Deskripsi

Description

Specification

Physical

●  1RU fixed form factor
●  Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+)
◦  48 SFP ports support 1 and 10 Gigabit Ethernet
◦  4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each
●  2 redundant power supplies
●  1 fan tray with redundant fans
●  1 I/O module with management, console, and USB flash memory ports

Performance

●  1.28-Tbps switching capacity
●  Forwarding rate of 950 mpps
●  Line-rate traffic throughput (both Layer 2 and 3) on all ports
●  Configurable Maximum Transmission Units (MTUs) of up to 9216 bytes (jumbo frames)

Hardware tables and scalability

MAC addresses

128,000

Number of VLANS

4096

Spanning-tree instances

●  Rapid Spanning Tree Protocol (RSTP): 512
●  Multiple Spanning Tree (MST) Protocol: 64

ACL entries

●  2000 ingress
●  1000 egress

Routing table

●  16,000 prefixes and 16,000 host entries *
●  8000 multicast routes *

Number of EtherChannels

64 (with vPC)

Number of ports per EtherChannel

32

Buffers

9 MB shared

Boot flash memory

2 GB

Power

Number of power supplies

2

●  Cisco Nexus 3064-X: Redundant for AC and DC power
●  Cisco 3064-T and 3064-32T: Redundant for AC power

Power supply types

●  AC (forward and reversed airflow)
●  DC (forward and reversed airflow)

Typical operating power

●  Cisco Nexus 3064-X
◦  143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs])
◦  177W (64p with SR optics at 100% load; 2 PSUs)
●  Cisco Nexus 3064-T
◦  362W (48p with 3m cables; 4 SR4 at 100% load)

Maximum power

●  Cisco Nexus 3064-X: 199W
●  Cisco Nexus 3064-T

AC PSUs

●  Input voltage
●  Frequency
●  Efficiency
●  100 to 240 VAC
●  50 to 60 Hz
●  89 to 91% at 220V

DC PSUs

●  Input voltage
●  Maximum current
●  Efficiency
●  -40 to -72 VDC
●  33A
●  85 to 88%

Typical heat dissipation

●  Cisco Nexus 3064-X
◦  488 BTU/hr (64p with Twinax at 100% load; 2 PSUs)
◦  605 BTU/hr (64p with SR optics at 100% load; 2 PSUs)
●  Cisco Nexus 3064-T
◦  1235 BTU/hr (48p with 3m cables; 4 SR4 at 100% load)

Maximum heat dissipation

●  Cisco Nexus 3064-X: 683 BTU/hr
●  Cisco Nexus 3064-T: 1553 BTU/hr

Cooling

Forward and reversed airflow schemes:

●  Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)
●  Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies)

Single fan tray with redundant fans

Hot swappable (must swap within 1 min)

Sound

Measured sound power (maximum)

●  Fan speed: 40% duty cycle
●  Fan speed: 60% duty cycle
●  Fan speed: 100% duty cycle
●  59.7 dBA
●  66.4 dBA
●  71.0 dBA
Cisco Nexus 3064-X, 3064-T, and 3064-32T Datasheet