Deskripsi

Technical Specifications

Item Specification
Dimensions with packaging (H x W x D) [mm (in.)] 1695 mm x 770 mm x 1350 mm (66.73 in. x 30.31 in. x 53.15 in.)
Dimensions without packaging (H x W x D) [mm (in.)] 1436 mm x 483 mm x 1144 mm (56.54 in. x 19.02 in. x 45.04 in.) (including mounting brackets)
Weight without packaging [kg (lb)] 262.8 kg (579.47 lb) (including two MPUs and filler panels)
Weight without packaging (full configuration) [kg (lb)] 569.6 kg (1255.97 lb)
Weight with packaging [kg (lb)] 335 kg (738.68 lb)
Cabinet installation standards A812
Chassis height [U] 32.3 U
Redundant MPUs 1:1
Redundant Switch fabrics N+M
Power supply mode
  • AC
  • HVDC
Number of power modules 20
Redundant power supply
  • Dual-input power supply system: N+1 backup is recommended.
  • Single-input power supply system: N+1 backup

Dual-input power supply is recommended to ensure reliability.

Rated input voltage [V]
  • AC: 220 V; 50 Hz/60 Hz
  • High-voltage DC (HVDC): 240 V/380 V
Input voltage range [V]
  • AC: 176–290 V; 45–65 Hz
  • High-voltage DC (HVDC): 188 V to 288 V or 260 V to 400 V
Maximum input current [A]
  • AC: 16 A @ 200 V; 18.5 A @ 176 V
  • High-voltage DC (HVDC): 18 A @ 188 V; 13 A @ 260 V
Maximum output power [W]
  • In 19+1 backup mode: 3000 W x 19 = 57000 W
  • In 20+0 backup mode: 3000 W x 20 = 60000 W
Certification
  • Compliance with safety standards
  • Compliance with EMC standards
  • Compliance with environment and environmental protection standards
Redundant fans Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation mode Heat dissipation using fans
Airflow direction Front-to-back airflow
Availability 0.9999970745
MTBF [year] 32.68 year
MTTR [hour] 1 hour
Long-term operating altitude [m (ft.)] ≤ 5000 m (16404 ft.) (When the altitude is between 1800 m and 5000 m (5906 ft. and 16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).)
Long-term operating relative humidity [RH] 5% RH to 85% RH, noncondensing
Long-term operating temperature [°C (°F)] 0°C to 40°C (32°F to 104°F)
Storage altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Storage relative humidity [RH] 5% RH to 95% RH, noncondensing
Storage temperature [°C (°F)] -40ºC to +70ºC (-40°F to +158°F)