Huawei CloudEngine 24*10/100/1000BASE-T ports, 4*10GE SFP+ ports (S5735-L24T4X-A1)

Rp20.612.700

SKU: S5735-L24T4X-A1 Kategori: , , Tag: , ,
Deskripsi

S5735-L24T4X-A1 Specification

Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.)
Chassis height [U] 1 U
Typical power consumption [W] 33.2 W
Typical heat dissipation [BTU/hour] 113.28 BTU/hour
Maximum power consumption [W] 45.6 W
Maximum heat dissipation [BTU/hour] 155.59 BTU/hour
MTBF [year] 62.05 year
MTTR [hour] 2 hour
Availability >0.99999
Noise at normal temperature (acoustic power) [dB(A)] 39 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 27.2 dB(A)
Number of card slots 0
Number of power slots 0
Number of fans modules 1
Redundant power supply Not supported
Long-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) (0 m to 1800 m altitude, non-industrial optical modules)

-5°C to +55°C (23°F to 131°F) (0 m to 1800 m altitude, industrial optical modules with transmission distances less than or equal to 10 km)

Short-term operating temperature [°C(°F)] Not supported
Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The switch cannot be started when the ambient temperature is lower than 0°C (32°F).

The operating temperature ranges from -5°C to +45°C (23°F to 113°F) when optical modules with transmission distances greater than or equal to 70 km are used.

Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH] 5% to 95%, noncondensing
Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode AC built-in
Rated input voltage [V] AC input: 100 V AC to 240 V AC, 50/60 Hz
Input voltage range [V] AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz
Maximum input current [A] 2 A
Memory 512 MB
Flash memory 512 MB
Console port RJ45
Eth Management port Not supported
USB Supported
RTC Not supported
RPS input Not supported
Service port surge protection [kV] 98011302:

Common mode: ±7 kV

98011302-001:

Common mode: ±2 kV

Power supply surge protection [kV] ±6 kV in differential mode, ±6 kV in common mode
Types of fans Built-in
Heat dissipation mode Heat dissipation with fan, intelligent fan speed adjustment
Airflow direction Air intake from left and front, air exhaustion from right
PoE Not supported