Ruijie High-Performance Large Campus Wireless Access Controller (RG-WS6512-L)
Rp160.503.780
Specifications
| Dimensions and Weight | RG-WS6512-L |
| Dimensions (W x D x H) | 440 mm x 340 mm x 43.6 mm (17.32 in. x 13.39 in. x 1.72 in.) |
| Rack height | 1 RU |
| Weight | Main unit: 5.9 kg (13.01 lbs)
Power module: 0.4 kg (0.88 lbs) A power module is delivered with the main unit. |
| Ports | RG-WS6512-L |
| Fixed service port | 8 x GE combo ports , when the combo port is used as an electrical port,
● Port 1 can be used as an out-of-band management port (MGMT). ● It supports 10/100/1000Base-T auto-negotiation. ● It supports Auto MDI/MDIX crossover. 4 x 10GE SFP + ports |
| Fixed management port | 1 x RJ45 console port
2 x USB ports |
| Status LED | 1 x system status LED
20 x service port LEDs |
| Button | 1 x Reset button
● Press the button for shorter than 3 seconds. Then the device restarts. ● Press the button for longer than 3 seconds. Then the device restores to factory settings. |
| Power Supply and Consumption | RG-WS6512-L |
| Max. power consumption | 70 W |
| Power module | 2 x RG-PA70I 70 W AC power modules
A power module is delivered with the main unit. You can buy one more optionally. |
| Input voltage | 100 V AC to 240 V AC, 50 Hz to 60 Hz |
| Input current | 10 A (steady state) |
| Output voltage | 12 V/5.83 A |
| Environment and Reliability | RG-WS6512-L |
| Temperature | Main unit operating temperature: 0°C to 45°C (32°F to 113°F)
Power module operating temperature: –10°C to+ 50°C (+14°F to +122°F) Main unit storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At an altitude between 3,000 m (9,843 ft.) and 5,000 m (16,404 ft.), every time the altitude increases by 220 m (722 ft.), the maximum temperature decreases by 1°C (1.8°F). |
| Operating altitude | 0 m to 5,000 m (0 ft to 16,404 ft) |
| Humidity | Operating humidity: 10% to 90% RH (non-condensing)
Storage humidity: 5% to 95% RH (non-condensing) |
| Fan | Built-in three fans (on the left side)
Right-to-left airflow Fan speed adjustment Fan fault alarm |
| Acoustic noise | < 78 dB |
| Mean Time Between Failure (MTBF) | 200,000 hours (22 years) at the operating temperature of 25°C (77°F) |