Schneider Circuit breaker ComPacT NSXm B (25kA at 415VAC), 3 Poles 3d, 40A rating TMD trip unit, compression lugs and busbar connectors (C11B3TM040B)

Rp1.518.613

Deskripsi

Spesifikasi

  • Activity
    PPCCB
  • Weight (in Kg)
    1.3
  • Ambient Air Temperature for Operation
    -25-70 °C
  • Ambient Air Temperature for Storage
    -50-85 °C
  • Depth
    80 mm
  • Height
    137 mm
  • Ip Degree of Protection
    IP40 conforming to IEC 60529
  • Net Weight
    1.06 kg
  • Width
    81 mm
  • Product or Component Type
    circuit breaker
  • [in] Rated Current
    40 A at 40 °C
  • Control Type
    toggle
  • Colour
    grey (RAL 7016)
  • Trip Unit Protection Functions
    LI
  • Trip Unit Technology
    thermal-magnetic
  • standards
    EN/IEC 60947
  • Device Application
    distribution
  • Range of product
    ComPacT NSXm new generation
  • Breaking Capacity
    50 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
    25 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
    20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  • Mounting Mode
    fixed
  • Device short name
    NSXm 100B
  • Operating altitude
    2000 m without derating
    5000 m with derating
  • Range
    ComPacT new generation
  • Trip unit name
    TM-D
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • Mechanical Durability
    20000 cycles
  • IK Degree Of Protection
    IK07 conforming to IEC 62262
  • Utilisation Category
    category A
  • 9 mm Pitches
    9 module
  • Network Frequency
    50/60 Hz
  • Suitability For Isolation
    yes conforming to IEC 60947-2
  • Trip Unit Rating
    40-40 A at 40 °C
  • Earth-Leakage Protection
    without
  • Breaking Capacity Code
    B 25 kA 415 V AC
  • Downside Connection
    front
  • Instantaneous Pick-up Adjustment Range
    600 A
  • Instantaneous Pick-up Adjustment Type Li
    fixed
  • Long Time Delay Adjustment Type
    fixed
  • Long Time Pick-up Adjustment Range
    0.7…1 x In
  • Long Time Pick-up Adjustment Type Lr
    adjustable
  • Upside Connection
    front
  • [Ue] Rated Operational Voltage
    690 V AC 50/60 Hz
  • Product Name
    ComPacT NSXm new generation
  • Local Signalling
    flag (green) for presence of auxiliary contacts
  • Connections Terminals
    compression lug/busbar
  • Poles description
    3P
  • [Ics] Rated Service Breaking Capacity
    50 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
    25 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
    20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
    10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ui] Rated Insulation Voltage
    800 V AC 50/60 Hz
  • Electrical Durability
    20000 cycles at 440 V In/2
    10000 cycles at 440 V In
    10000 cycles at 690 V In/2
    5000 cycles at 690 V In
  • Power Dissipation Per Pole
    3.46 W
  • Connection pitch
    35 mm with spreaders
    27 mm without spreaders
  • Mounting position
    horizontal and vertical
    flat on the back
  • Network type
    AC
  • Number of slots
    1 slot(s) for auxiliary switch OF
    1 slot(s) for alarm switch SD
    1 slot(s) for voltage release MN or MX
  • Pollution degree
    3 conforming to IEC 60664-1
  • Protected poles description
    3D