Range of product | Easergy P3 |
---|---|
Product or component type | Protection relay |
Relay application | Universal |
product reference | P3U20-6AAA1ADAA |
power supply | 48…230 V AC/DC |
measuring inputs | : 1/5 A CT phase current 3 : 1/5 A CT residual current 1 : 100 V/110 V VT voltage 1 |
Number of sensors | 0 temperature sensor(s) 0 arc sensor(s) |
number of Digital Inputs (DI) | 10 |
number of Digital Outputs (DO) | 1 watchdog 5 |
number of analogue inputs | 0 |
number of analogue outputs | 0 |
communication ports | USB port 1 front LC 2 rear |
communication protocols | IEC 61850 ed. 1 IEC 61850 ed. 2 IEC 60870-5-101 DNP3 TCP Modbus TCP EtherNet/IP |
Redundancy communication port protocol | RSTP PRP |
Cybersecurity | Port hardening Password protection |
protection functions | Phase undercurrent 37 Negative sequence overcurrent 46 Broken conductor 46 I2/I1 Excessive starting time, locked rotor 48/51LR Thermal overload protection 49 Phase overcurrent 50/51 Earth fault overcurrent 50N/51N Breaker failure 50BF Switch ON to fault (SOTF) Capacitor bank unbalance 51C Capacitor overvoltage 59C Neutral voltage displacement 59N Motor restart inhibition 66 Directional earth fault 67N Transient earth fault 67NI CT supervision 60 VT supervision 60 H2 detection 68H2 H5 detection 68H5 Recloser 79 Lockout relay 86 Cold load pick-up Programmable stages 99 Programmable curve |
Arc flash protection | No |
measurement functions | Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Voltage phase to earth Voltage phase to phase Voltage zero sequence Voltage positive sequence Voltage negative sequence Voltage ratio of negative and positive Short circuit fault reactance Fault location current Earth fault reactance Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Voltage phasor diagram view Current phasor diagram view Current 2nd, 15th harmonics with THD Voltage 2nd, 15th harmonics with THD Voltage interruption Condition monitoring CB wear |
control functions | Switchgear control and monitoring Programmable switchgear interlocking Local control on single-line diagram Local control with I/O keys Local/remote control 2 function keys Mobile application with Easergy SmartApp Web-server Programmable logic |
controllable switchgear devices | 2 controlled + 4 displayed |
number of setting groups | 4 |
monitoring functions | Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring |
logs and records | Event recording Disturbance recording Tripping context |
Switchgear diagnosis type | CT supervision Trip circuit supervision ANSI code: TCS |
Connections – terminals | Screw removable (digital input/output) Ring lugs removable (current transformer) Pin removable (voltage transformer) |
Operating threshold | 24…230 V AC/DC |
---|---|
web server | Embedded HTTP server |
Software name | EcoStruxure Power Device ESetup Easergy Pro |
Display type | And LCD 128 x 64 pixels with single line diagram |
Number of key | 2 customizable |
Local signalling | 4 LEDs 8 LEDs programmable |
Standards | IEC |
Height | 169.5 mm |
Width | 170 mm |
Depth | 205 mm |
Net weight | 2.5 kg maximum |
Electromagnetic compatibility | Emission tests conforming to IEC/EN 60255-26 ed. 3 Emission tests class A conforming to CISPR 11 Emission tests class A conforming to CISPR 22 EMC immunity conforming to IEC/EN 60255-26 ed. 3 EMC immunity conforming to EN/IEC 61000-4-18 EMC immunity level 4 conforming to EN/IEC 61000-4-2 EMC immunity level 3 conforming to EN/IEC 61000-4-3 EMC immunity level 4 conforming to EN/IEC 61000-4-4 EMC immunity level 3 conforming to EN/IEC 61000-4-5 EMC immunity level 3 conforming to EN/IEC 61000-4-6 EMC immunity conforming to EN/IEC 61000-4-8 EMC immunity level 5 conforming to EN/IEC 61000-4-9 EMC immunity conforming to EN/IEC 61000-4-29 EMC immunity conforming to EN/IEC 61000-4-11 EMC immunity conforming to EN/IEC 61000-4-17 |
---|---|
Mechanical robustness | Vibrations (level: class II) conforming to IEC 60255-21-1 Vibrations: Fc conforming to IEC 60068-2-6 Shocks (level: class II) conforming to IEC 60255-21-2 Shocks: Ea conforming to IEC 60068-2-27 Seismic tests method A (level: class II) conforming to IEC 60255-21-3 Bumps (level: class II) conforming to IEC 60255-21-2 Bumps: Ea conforming to IEC 60068-2-27 |
climatic withstand | Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2 Exposure to cold Ad tests conforming to EN/IEC 60068-2-1 Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30 Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78 |
Ambient air temperature for operation | -40…65 °C |
Ambient air temperature for storage | -40…70 °C |
IP degree of protection | IP54 conforming to IEC 60529 |
Relative humidity | 0…95 %, without condensation |
maximum operating altitude | 2000 m |
Protective treatment | Conformal coating |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 16 cm |
Package 1 Width | 21.5 cm |
Package 1 Length | 27.5 cm |
Package 1 Weight | 3.5 kg |
Datasheet-Easergy P3 Protection Relays_REL52036.pdf
Produk Terkait
INBOW DOOS 1G PLASTIK WVJ 5911 PANASONIC
Rp6.768
OUTBOW DUS SCHNEIDER E238 MOUNTING BOX W/O TERM
Rp25.090
SAKLAR DOUBLE GRACIO BROCO 4162 2G 1W WHITE
Rp25.689
SAKLAR SINGLE HOTEL BROCO GALLEO G163-55S WHITE
Rp23.863
STOP KONTAK AC BROCO GALLEO 3PIN G155-55S WHITE
Rp42.531
STOP KONTAK ARDE GRACIO BROCO 4151 1G CREAM
Rp18.929
STOP KONTAK TELP GRACIO BROCO 4171 1G WHITE
Rp71.552
STOP KONTAK TV GRACIO BROCO 4183 1G CREAM
Rp51.757